It appears that the current practices of dissolution testing follow two separate and parallel paths. For example: a simple question would be “how to conduct a dissolution test?” Common response usually is to use any of the “approved” dissolution apparatuses such as USP Paddle/Basket with associated experimental conditions such as 1L capacity glass/plastic vessel, 900 mL or less medium (buffer or water), 50/75/100 rpm, if needed, some solubilising agent (e.g SLS) added to it along with all the instructions/suggestions to control the specifications and operation of the apparatuses/testing.

In reality, however, the question is usually not intended towards the available choices of apparatuses or associated experimental conditions but seeking a methodology to determine dissolution characteristics of a product. To answer this question, one has to have a standardized apparatus with fixed associated experimental conditions. This apparatus along with its associated experimental condition must be capable of providing dissolution results (verifiable independently from the dissolution tester) of a reference product. Therefore, for determining dissolution characteristics, one has to have a standardized tester (apparatus and associated fixed experimental conditions) and reference product with known dissolution characteristics. Once an analyst is able to determine the acceptable results of the reference product, using standardized tester, then this tester is to be used to determine the unknown dissolution characteristics of the test products. If the results are not as desired or expected then analyst must work with the product (formulation/manufacturing), and NOT with the experimental conditions, which would void the dissolution test and results.

The current situation is that neither a standardized a dissolution tester nor a reference product is available to the analyst, but technique is expected to provide dissolution characteristics of a test product. The analyst has to be confused and frustrated, as well as the pharmaceutical industry, which loses significant amounts of money for conducting dissolution testing of limited value.

To address this confusion a new approach in dissolution testing using a new spindle has been suggested. For further discussion in this regard please see the title “Know Ur Product” and other links (1, 2, 3, 4).

Donate

Your support is needed in providing free and unbiased scientific work. Please donate (any amount). Thanks


Archives
Links

PharmacoMechanics

This will close in 0 seconds